FFC Cable:
Specification 1) Conductor resistance: a) 0.1 x 1.27 (T x W): <0.21 omega/m b) 0.1 x 0.8 (T x W): <0.26 omega/m c) 0.1 x 0.6 (T x W): <0.38 omega/m d) 0.1 x 0.5 (T x W): <0.42 omega/m e) 0.1 x 0.3 (T x W): <0.68 omega/m f) 0.05 x 1.27 (T x W): <0.42 omega/m g) 0.05 x 0.8 (T x W): <0.52 omega/m h) 0.05 x 0.6 (T x W): <0.58 omega/m i) 0.05 x 0.5 (T x W): < 0.81 omega/m j) 0.05 x 0.3 (T x W): <1.36 omega/m k) 0.035 x 1.27 (T x W): <0.57 omega/m l) 0.035 x 0.8 (T x W): <0.74 omega/m m) 0.035 x 0.6 (T x W): <0.82 omega/m n) 0.035 x 0.5 (T x W): <1.15 omega/m o) 0.035 x 0.3 (T x W): <1.82 omega/m 2) Insulation resistance: > 50 omega/m 3) Dielectric strength: no breakdown, AC 500V for 1 min 4) Open /short test: pass, DC 3.0V 0.1m A 5) Heat resistance: insulation resistance and dielectric strength pass 6) Heat cycle test: insulation resistance and dielectric strength pass, -40-25-85-25C for 5 cycles 7) Moisture resistance: insulation resistance and dielectric strength pass, 40C, 95% RH for 96h 8) Flame test: pass UL VW-1 9) Flexing test: > 3,000,000 cycles, 10R/10cm at 70 cycles/min 10 Bending test (180 degree): (clip the point of supporting tape)100 cycles-90 to 90/600g/0.5R 11) Abrasion test: > 10,000 cycles, 5R/600g, 60 cycles/min
If this offer has interested you, please, fill the form of inquiry and you receive the answer in ASAP. |
|
|
 |